EMF vs Temperature Tables

Complete millivolt reference tables for Type K, N, J, T and E thermocouples per IEC 60584-1:2013. Cold junction at 0 °C.

Type K EMF reference table, 0 °C cold junction, per IEC 60584-1:2013.

Using these tables

  1. Confirm the reference junction is at 0 °C, or apply cold-junction compensation before comparing.
  2. Look up the EMF at your process temperature in the table for the type actually installed.
  3. Compare the reading against the tolerance band for the class of wire you are using before judging accuracy.

Type K — Chromel / Alumel (IEC 60584-1)

EMF in mV for Type K (Chromel / Alumel). Reference junction at 0 °C. Tolerance: ±1.5 °C (0–375 °C), ±0.4% (375–1000 °C).

Temperature (°C)EMF (mV)
−200−5.891
−100−3.554
00.000
1004.096
2008.138
30012.209
40016.397
50020.644
60024.905
70029.129
80033.275
90037.326
100041.276
110045.119
120048.838
130052.410
137054.819

Data source: IEC 60584-1:2013. Full tables for Type N, J, T and E available on request.

Frequently Asked Questions

What reference junction temperature do these EMF tables use?

0 °C. All values are given in millivolts for a cold junction held at 0 °C, per IEC 60584-1:2013.

What is the EMF of a Type K thermocouple at 1000 °C?

41.276 mV with the reference junction at 0 °C. The table below runs from −200 °C to +1370 °C in 100 °C steps.

Which tolerance applies to the Type K table?

±1.5 °C between 0 °C and 375 °C, and ±0.4% of reading from 375 °C to 1000 °C. That is the Class 1 band defined by IEC 60584-1.

Can you supply tables for Type N, J, T and E?

Yes. Full EMF tables for those types are available on request, and we can issue calibration certificates against the specific batch you receive.

Bottom line: Use these values with a 0 °C reference junction: if your instrument uses a different reference, apply cold-junction compensation before comparing readings. Full IEC 60584-1 tables for Type N, J, T and E are available on request, as are batch-specific calibration certificates.

Need EMF data for a specific temperature or alloy?

Our engineering team can supply calibration certificates and custom temperature-EMF tables for your exact batch.

Add RAS Thermo as a preferred source on Google