RAS ThermalRequest Quote
Product category

Type T Thermocouple Wire — Copper / Constantan

Temperature range: −200 … +350 °C. Full batch-to-furnace traceability. IEC 60584-1 Class 1, ASTM E230.

Type T Thermocouple Wire: Copper / Constantan, −200 … +350 °C
Alloy composition
Positive Leg

Copper (Cu 99.9%)

Negative Leg

Constantan (CuNi 55/45)

EMF Tolerance

±0.5°C (−40–125°C) / ±0.4% (125–350°C)

Key characteristics
Advantage

Best accuracy in sub-zero range (±0.5°C). Excellent corrosion resistance. Preferred for cryogenic and pharmaceutical applications.

Limitation

Copper leg oxidises above 350°C. Limited upper temperature range.

Technical Specifications

PropertySpecification
Diameter Rangeφ0.025mm – φ5.0mm
Tolerance±0.005mm (fine) / ±0.02mm (standard)
Temperature Range−200 … +350 °C
StandardsIEC 60584-1 Class 1 / ASTM E230 / DIN EN 60584
Surface FinishBright / Oxidised / Electro-polished
PackagingDIN 125 spool / Coil / Custom reel
Coil Weight5kg / 10kg / 20kg standard
TraceabilityFurnace batch number engraved on spool

Available Product Forms

How to specify Type T Thermocouple Wire

  1. Confirm the alloy for your operating temperature — Copper / Constantan, rated −200 … +350 °C.
  2. Check the atmosphere before ordering — Copper leg oxidises above 350°C. Limited upper temperature range.
  3. Choose the product form — Bare Wire or Stranded Wire. For Type T Thermocouple Wire the deciding factor is the service condition: best accuracy in sub-zero range (±0.5°C). Excellent corrosion resistance. Preferred for cryogenic and pharmaceutical applications.
  4. Fix the conductor diameter within φ0.025mm – φ5.0mm (±0.005mm (fine) / ±0.02mm (standard)).
  5. Quote against IEC 60584-1 Class 1 and request the MTC / EMF calibration certificate with the furnace batch number — state which Type T Thermocouple Wire form you need so the certificate scope matches the delivered conductor.

Frequently Asked Questions

Why is Type T used for cryogenic measurement?

It is the most accurate base-metal thermocouple below zero at ±0.5 °C, with excellent corrosion resistance in moist environments.

What is the temperature range of Type T?

−200 °C to +350 °C. The copper positive leg oxidises above 350 °C, which is why the type is used for low-temperature rather than furnace service.

Which industries specify Type T?

Cryogenics, pharmaceutical autoclave validation and clean-room instrumentation — anywhere sub-zero accuracy and corrosion resistance matter.

What tolerance does Type T hold?

±0.5 °C, the tightest of the base-metal types, supplied to IEC 60584-1 Class 1 / ASTM E230.

Bottom line: Type T is the accuracy choice at the cold end: ±0.5 °C below zero over a −200 °C to +350 °C range, with good corrosion resistance in moist service. It is not a furnace type — the copper leg oxidises above 350 °C.

Ready to order Type T Thermocouple Wire?

Specify Type T Thermocouple Wire type, diameter, tolerance class and quantity — we reply with price and lead time within one business day.

Add RAS Thermo as a preferred source on Google