Type N Bare Wire
Nicrosil / Nisil
Solid single-strand thermocouple wire. φ0.025mm ultra-fine to φ5.0mm standard. Bright or oxidized finish.
Type N Bare Wire: φ0.025mm – φ5.0mm, −270°C to +1300°C, IEC 60584-1 Class 1
- Ø range
- φ0.025mm – φ5.0mm
- Temp
- −270°C to +1300°C
- EMF tol.
- ±1.5°C (0–375°C) / ±0.4% (375–1000°C)
- Testing
- 100%
Technical Specifications
Type N Bare Wire — Nicrosil / Nisil at −270°C to +1300°C, solid single strand from φ0.025mm – φ5.0mm, supplied to IEC 60584-1 Class 1.
| Property | Specification |
|---|---|
| Positive Leg | Nicrosil (NiCrSi 84.4/14.2/1.4) |
| Negative Leg | Nisil (NiSiMg 95.4/4.4/0.15) |
| Temperature Range | −270°C to +1300°C |
| Diameter Range | φ0.025mm – φ5.0mm |
| Diameter Tolerance | ±0.005mm (fine) / ±0.02mm (standard) |
| EMF Tolerance | ±1.5°C (0–375°C) / ±0.4% (375–1000°C) |
| Standards | IEC 60584-1 Class 1 / ASTM E230 / DIN EN 60584 |
| Surface Finish | Bright / Oxidized / Electro-polished |
| Condition | Hard (cold-drawn) / Soft (annealed) / Bright finished |
| Packaging | DIN 125 spool / Coil / Custom reel |
| Coil Weight | 5kg / 10kg / 20kg standard |
| Testing & Traceability | 100% eddy-current + resistance + dimensional · MTC · EMF calibration certificate · Furnace batch traceability |
How to specify Type N Bare Wire
- Confirm the alloy for your operating temperature — Nicrosil / Nisil, rated −270°C to +1300°C in air.
- Pick the conductor diameter from φ0.025mm – φ5.0mm (diameter tolerance ±0.005mm (fine) / ±0.02mm (standard)) — solid single-strand Nicrosil / Nisil at the ultra-fine end of the −270°C to +1300°C range.
- Choose the temper condition for this N · Nicrosil / Nisil wire — Hard (cold-drawn) / Soft (annealed) / Bright finished. The temper is chosen for the solid N sensing element held in the furnace or panel.
- Choose the surface finish for N · Nicrosil / Nisil — Bright / Oxidized / Electro-polished. Finish is selected for the atmosphere the N element will sit in.
- Choose the packaging — DIN 125 spool / Coil / Custom reel, standard coil weights 5kg / 10kg / 20kg standard. Spooled to protect the N solid conductor in transit and handling.
- Quote Type N Bare Wire against IEC 60584-1 Class 1 and request the MTC / EMF calibration certificate with the batch number for traceability.
Which thermocouple type fits the job
These are the N-type ranges as they apply to the solid single-strand form described on this page. Confirm the type first, then pick the conductor diameter.
| Type | Alloy | Range | EMF tolerance |
|---|---|---|---|
| K | Chromel / Alumel | −200 … +1370 °C | ±1.5°C (0–375°C) / ±0.4% (375–1000°C) |
| N this page | Nicrosil / Nisil | −270 … +1300 °C | ±1.5°C (0–375°C) / ±0.4% (375–1000°C) |
| T | Copper / Constantan | −200 … +350 °C | ±0.5°C (−40–125°C) / ±0.4% (125–350°C) |
Verification & quality evidence
- IEC 60584-1 Class 1 / ASTM E230 / DIN EN 60584
- 100% eddy-current + resistance + dimensional · MTC · EMF calibration certificate · Furnace batch traceability
- Third-party testimonials and site references are being collected for this product line — ask for Type N Bare Wire reference contacts in comparable static installations when you request a quote.
Frequently Asked Questions
What makes Type N more stable than Type K above 1000 °C?
The Nicrosil positive leg (NiCrSi 84.4/14.2/1.4) contains 1.4% silicon, which forms a protective SiO₂ sub-layer and suppresses the chromium oxidation that causes green rot. Type N drift stays within ±1 °C after 500 h at 1000 °C.
What temperature range and diameters does Type N bare wire cover?
−270 °C to +1300 °C, in diameters from φ0.025 mm to φ5.0 mm.
Where is Type N bare wire specified?
Vacuum furnaces, aerospace pyrometry to AMS 2750, gas turbine exhaust monitoring and semiconductor processes — wherever sensor replacement is costly or drift over a long service interval matters.
Bottom line: Type N Bare Wire (Nicrosil / Nisil) covers −270°C to +1300°C across φ0.025mm – φ5.0mm, with EMF tolerance ±1.5°C (0–375°C) / ±0.4% (375–1000°C). Supplied to IEC 60584-1 Class 1 with 100% EMF testing, MTC and furnace batch traceability.