THERMOCONDUCT
ThermoConduct
RAS Thermal Co., Ltd. Doc No: TC-DS-001 Rev.08
Date: August 2026

Thermocouple Alloy Conductor — Product Datasheet

Type K, N, J, T, E — Bare Wire, Stranded Wire & Alloy Ingots / Wire Rods. φ0.025mm to 5.0mm.

−200 to +1370 °C
φ0.025 – 5.0 mm
IEC 60584-1 / ASTM E230
ISO 9001:2015

1. Product Overview

RAS Thermal manufactures precision thermocouple alloy conductors with full in-house control from vacuum induction melting to ultra-fine wire drawing. Our conductors are used in aerospace engine testing, power generation turbines, petrochemical reformers, industrial heat treatment furnaces and automotive R&D facilities worldwide. Every metre of wire is traceable to a unique furnace batch number with full chemical composition and EMF calibration data archived and retrievable by furnace batch number.

2. Available Thermocouple Types

TypePositive Leg (+)Negative Leg (−)Temp. RangeSensitivity
Type KChromel (NiCr 90/10)Alumel (NiAl 95/5)−200 to +1370 °C~41 µV/°C
Type NNicrosil (NiCrSi)Nisil (NiSiMg)−270 to +1300 °C~39 µV/°C
Type JIron (Fe 99.5%)Constantan (CuNi 55/45)−40 to +750 °C~55 µV/°C
Type TCopper (Cu 99.9%)Constantan (CuNi 55/45)−200 to +350 °C~43 µV/°C
Type EChromel (NiCr 90/10)Constantan (CuNi 55/45)−200 to +900 °C~68 µV/°C

3. Product Forms

FormDescriptionTypical Diameter
Bare WireSolid single-strand conductor, bright or oxidised finishφ0.025 – 5.0 mm
Stranded Wire7, 19 or 37 strand constructions for flexibilityφ0.1 – 5.0 mm
Alloy Ingots / Wire RodVacuum-melted thermocouple alloys, cast ingot or φ5.5 mm rodφ5.5 mm rod

4. Technical Specifications

Diameter Tolerance±0.005 mm (fine) / ±0.02 mm (standard)
EMF Tolerance (Class 1)±1.5 °C (0–375 °C) / ±0.4% (375–1000 °C)
Surface FinishBright / Oxidised / Electro-polished
ConditionHard (cold-drawn) / Soft (annealed) / Bright finished
PackagingDIN 125 spool / DIN 160 spool / Coil / Custom reel
Coil Weight5 kg / 10 kg / 20 kg standard
TraceabilityFurnace batch number engraved on every spool
Test Data ArchiveRetrievable by batch number
Third-Party InspectionSGS / Bureau Veritas available on request

5. Applicable Standards

IEC 60584-1:2013 — Thermocouples — Part 1: EMF specifications and tolerances
ASTM E230/E230M — Standard Specification for Temperature-EMF Tables for Standardized Thermocouples
DIN EN 60584 — German adoption of IEC 60584
JIS C 1602 — Japanese Industrial Standard for Thermocouples
GB/T 16839 — Chinese National Standard for Thermocouples
AMS 2750F — Pyrometry (aerospace heat treatment)

6. Ordering Information

Specify: Thermocouple Type | Product Form | Diameter | Condition | Tolerance Class | Quantity (kg or m) | Packaging | Surface Finish | Standard Required
Email: info@rasthermo.com  |  Technical: engineering@rasthermo.com